CC2 100A HIMOINSA ATS

CC2 100A HIMOINSA ATS
CC2 100A HIMOINSA ATS
CC2 100A HIMOINSA ATS
CC2 100A HIMOINSA ATS
CC2 100A HIMOINSA ATS
CC2 100A HIMOINSA ATS
CC2 100A HIMOINSA ATS
CC2 100A HIMOINSA ATS
CC2 100A HIMOINSA ATS
10,701 zł
Ex Tax: 8,700 zł
  • In stock: 4
  • Model: CC2-100A
  • Weight: 35.00kg
  • Dimensions: 500.00mm x 250.00mm x 700.00mm
  • SKU: CC2100A
  • Manufacturer Code: ATS-CC2100A

CC2 100A

CC2 100A   is a complete SZR - ATS system designed to work with power generators

Data sheet

Download the data sheet for the CC2 100A SZR-ATS system

CC2-100A - has its own CEC7 controller, which is responsible for the correct operation of the SZR-ATS system.
Our systems can work both with HIMOINSA generators and generators from other manufacturers.

Communication between the SZR-ATS system and the SZR - GENERATOR can be carried out in two ways. In the case of HIMOINSA generators, communication is performed via the CAN bus.
When the system is to work with a generator from another manufacturer, the SZR-ATS system provides a start signal to an external unit, which should be prepared for automatic operation.
The connection of the control system communication between the GENERATOR - SZR - is standardly made using 4 conductors. Two power conductors and two for CAN or REMOTE START.
The power connection for loads - is easily accessible, solid and well-designed so that there are no problems with connecting different cables and wires with different conductor cross-sections.
A very simple, logical and intuitive installation saves time and allows our systems to operate even up to 1 kilometre away from the generator.

In this model of the SZT-ATS - CC2 100A system, the main executive component is a set of industrial contactors designed for continuous operation.
They are protected by both a mechanical and electrical interlock. Thanks to this solution, there is no possibility of simultaneous contact between voltages from the MAINS and the GENERATOR.

The SZR- ATS system can operate in Manual or Automatic mode (MAN - AUTO)
In manual mode, the operator has full control.
We can manually switch the generator on and off, and switch from the mains position to the generator position. Everything is controlled through the simple and clear display of the CEC7 controller.

HIMOINSA CEC7 controller for SZR-ATS system

In automatic mode, everything is supervised by the HIMOINSA CEC7 controller - the controller of the SZR-ATS system.

The SZR-ATS system will operate automatically - start the generator and switch to generator power when one of the following irregularities occurs:
- Mains voltage failure
- Failure of one of the mains phases
- Mains voltage too low
- Mains voltage too high
- Mains frequency too low
- Mains frequency too high
- Incorrect mains phase sequence
- Change in phase rotation direction

Standard parameters and capabilities of our SZR - ATS system

READINGS FROM THE HIMOINSA GENERATOR
- Line-to-line voltage reading, three-phase [V]
- Phase-to-neutral voltage reading, single-phase [V]
- Current reading [A]
- Frequency reading [Hz]
- Apparent power reading [kVA]
- Active power reading [kW]
- Reactive power reading [kVAr]
- Power Factor reading [PF]

MAINS READINGS
- Line-to-line voltage reading, three-phase [V]
- Phase-to-neutral voltage reading, single-phase [V]
- Frequency reading [Hz]
- THD reading

SAFETY
- Emergency STOP

GENERATOR PROTECTION
- Protection against too high frequency
- Protection against too low frequency
- Protection against too high voltage
- Protection against too low voltage
- Protection against excessive asymmetry
- Protection against incorrect phase sequence

FUNCTIONALITY OF THE HIMOINSA SZR-ATS SYSTEM
- Full manual - automatic operation capability
- Memory of the last 100 alarms
- Remote start
- Multi-language support
- Remote monitoring capability
- TEST mode
- Full time settings: switch-off times, switch-on times, stop time in position - 0 - a very important element, transfer times and reaction times of the SZR-ATS system
- Possibility of individual settings and activation levels - activation thresholds - very important especially in installations where photovoltaic systems are connected to the grid

POSSIBLE COMMUNICATION WITH THE CONTROLLER -  *option
- Modbus TCP*
- Modbus RS485*
- C2 LAN Ethernet*
- C2CLOUD - GPS - GSM 3G modem*
- SNMP*
- PROFIBUS*

Components of the HIMOINSA 63A 100A 125A SZR-ATS system

1 - ENCLOSURE - IP55 - POURED GASKET
2 - CEC7 CONTROLLER DISPLAY
3 - CEC7 CONTROLLER - CAN communication
4 - EMERGENCY STOP BUTTON
5 - FOUR-POLE CONTACTORS WITH MECHANICAL AND ELECTRICAL INTERLOCK
6 - CONNECTION TERMINALS and CABINET EARTHING